Home / Industrial Case Studies

ALUP Customer Success Stories & Energy ROI in Egyptian Factories

How ALUP compressed air modernizations perform in Egyptian industrial plants: lower electricity bills, fewer thermal trips and cleaner, drier air for demanding production lines.

Illustrative example: this study shows typical results for similar projects and does not describe a named customer. Actual savings depend on each plant.

20–45%
Typical compressor energy saving with VSD
+3°C
Pressure dew point with ADQ refrigerant dryers
45°C
Ambient temperature we design stations for
4
Sectors: plastics, food, automotive, textiles
Plastics & Injection Molding 10th of Ramadan Industrial City, Egypt

Plastics Manufacturer Cuts Compressor Energy Use by 34% with ALUP EVOLUTO in 10th of Ramadan

34%
Energy Consumption Reduced
4.8% → 0.4%
Plastic Scrap Rate

Case study: How a leading plastics injection plant in 10th of Ramadan reduced compressor power consumption by 34% and cut its scrap rate with an ALUP EVOLUTO 75 kW compressor.

Equipment
System Deployed:
ALUP EVOLUTO 75 kW (iPM VSD)
Food & Beverage Packaging Sadat City Industrial Zone, Menoufia

Food Packaging Plant Achieves Zero Moisture & NFSA Compliance in Sadat City

0.00%
Oil Contamination in Air Line
18 Hrs
Monthly Downtime Saved

How a dairy packaging plant in Sadat City eliminated moisture contamination, passed NFSA food hygiene audits, and cut line downtime with an ALUP ALLEGRO clean air system.

Equipment
System Deployed:
ALUP ALLEGRO 45 kW
Automotive & Heavy Metal Fabrication 6th of October Industrial Zone 3, Giza

Automotive Stamping Plant Secures 99.8% Uptime with ALUP LARGO in 6th of October

99.8%
Continuous Operational Uptime
0 Hours
Unplanned Shutdowns in 8,500 hrs

Case study: How an automotive supplier in 6th of October eliminated summer thermal trips and achieved 99.8% uptime with an ALUP LARGO 55 kW direct-drive compressor.

Equipment
System Deployed:
ALUP LARGO 55 kW Direct Drive
Textiles & Yarn Spinning Borg El Arab Industrial Zone, Alexandria

Textile Mill in Borg El Arab Cuts Air System Energy by 28% via Ultrasonic Leak Audit & VSD

28%
Total Air System Energy Saved
38
Pipe Leaks Found & Fixed

Case study: How an export textile mill in Borg El Arab cut its compressed air energy use by 28% through Flowva Air ultrasonic leak audits and an ALUP EVOLUTO 90 kW compressor.

Equipment
System Deployed:
ALUP EVOLUTO 90 kW iPM
Zero-Downtime Plant Audit

Ready to Achieve Similar Energy Savings in Your Plant?

Flowva Air engineers deploy calibrated data-loggers and ultrasonic leak detectors to your factory floor and deliver an engineering report showing the achievable energy saving before any purchase decision.

01014645825